دليل شراء الهزازات الكهروديناميكية عالية التردد

دليل شراء الهزازات الكهروديناميكية عالية التردد



High Frequency  Electrodynamic shakers Purchasing Guide

Selecting the right high frequency vibration test machine is crucial to meet the specific needs and requirements of your industry. This purchasing guide will provide you with detailed information and specific data to help you make an informed decision. It takes into consideration industry pain points, hotspots, and international standards. Please find below the detailed guide in الإنكليزية.

شروط الاختبار المطلوبة

لتحديد منصة كهربائية مناسبة ، من المهم تقديم المعلومات التالية فيما يتعلق بظروف اختبار الاهتزاز لديك:
1. نطاق التردد (بالهرتز ، هرتز) لاختبار الاهتزاز.
2. Magnitude of shaker test parameters such as acceleration (m/s² or g), displacement (mmp-p or p), velocity (m/s), or acceleration spectral density (PSD) values (g²/Hz or m²/s³).
3. اتجاه اختبار الاهتزاز: سواء كان اختبارا رأسيا أحادي المحور أو اختبارا ثلاثي المحاور (XYZ).
4. الأبعاد (الطول والعرض والارتفاع) ووزن عينة الاختبار.
5. وزن عينة الاختبار (بالكيلوغرام ، كجم).

حساب اختيار المنصة الكهربائية
بناء على الحد الأقصى لأبعاد ووزن عينة الاختبار ، اختر منصة تمدد رأسية.
The electric platform acts as the vibration source, and its working platform size is small, mainly used for fixture installation and expansion. Therefore, determine the size and weight of the expansion platform or fixture before the selection calculation. The main technical parameters of the vertical expansion platform are its dimensions, weight, and upper frequency limit. The maximum dimensions of the test specimen should be smaller than or equal to the expansion platform size, and the upper frequency limit of the vibration test should be smaller than or equal to the vertical expansion platform's upper frequency limit. Therefore, the dimensions and weight of the expansion platform can be determined based on the maximum dimensions and highest test frequency of the test specimen. The following data is for reference purposes only, as the specifications of the vertical platform or horizontal slide platform in different vibration equipment configurations may vary due to the different materials used.

اختر منصة انزلاق أفقية بناء على اتجاه اختبار الاهتزاز

إذا كان اختبار الاهتزاز لعينة الاختبار مطلوبا فقط في الاتجاه الرأسي ، فإن منصة التمدد الرأسي كافية. ومع ذلك ، بالنسبة لاختبارات الاهتزاز العامة التي تتطلب اهتزازا ثلاثي المحاور (محوريا) لعينة الاختبار ، يجب أن يحاكي الموضع الثابت أثناء اختبار الاهتزاز الموضع الثابت لعينة الاختبار في حالة العمل أو النقل قدر الإمكان.
إذا لم تكن هناك متطلبات محددة لموضع التثبيت لعينة الاختبار في حالة عملها أو نقلها ، أي إذا كان تغيير مركز ثقل عينة الاختبار عن طريق قلبها لا يؤثر على أدائها ، فيمكن تحقيق اهتزاز ثلاثي المحاور لعينة الاختبار عن طريق تحديد اتجاه اهتزاز المنصة الكهربائية وتغيير مركز ثقل عينة الاختبار. في هذه الحالة ، لا يلزم سوى منصة توسع رأسية. ومع ذلك ، بالنسبة لعينات الاختبار الكبيرة ، تكون منصة الانزلاق الأفقية كافية بسبب الحجم الكبير للمنصة الكهربائية المطلوبة.
إذا كانت هناك متطلبات محددة لموضع التثبيت لعينة الاختبار في حالة عملها أو نقلها ، أي إذا كان تغيير مركز ثقل عينة الاختبار عن طريق قلبها يؤثر على أدائها ، فيجب تغيير اتجاه اهتزاز المنصة الكهربائية لتحقيق اهتزاز ثلاثي المحاور لعينة الاختبار مع الحفاظ على مركز ثقل عينة الاختبار دون تغيير. في هذه الحالة ، يلزم وجود منصة تمدد رأسية وطاولة انزلاق اهتزاز أفقية.
The technical specifications of the SC series horizontal slip table produced by ALITETSING——JOEO are provided below for reference. The selection process for the horizontal slide platform is similar to that of the vertical expansion platform. Note: The higher the upper frequency limit, the higher the required rigidity coefficient and the heavier the platform components. The calculation for the maximum acceleration in vibration testing is as follows:

تنقسم شروط اختبار الاهتزاز الجيبي بشكل عام إلى:
1) Constant Acceleration Swept Sine Test: f1--f2, Acceleration A1. In this test, the maximum acceleration within the frequency range from f1 to f2 is A1. The conversion formula for displacement D during swept frequency vibration is: D = A1×103/(2πf)2. Thus, the maximum displacement is D1MAX = A1×103/(2πf1)2.
2) Constant Velocity Swept Sine Test: f1--f2, Velocity V. The conversion formula between velocity and acceleration is: A = (2πf)V, where A is in m/s² and V is in m/s. Thus, the maximum acceleration is A2MAX = (2πf2)V. The conversion formula for displacement D during swept frequency vibration is: D = V×103/(2πf). Thus, the maximum displacement is D2MAX = V×103/(2πf1).
3) Constant Displacement Swept Sine Test: f1--f2, Displacement D. The conversion formula between displacement D and acceleration A is: A = (2πf)2D×10-3, where A is in m/s² and D is in mm. Thus, the maximum acceleration is A3MAX = (2πf)2D×10-3, and the maximum displacement is D.
4) اجتاحت شريحة متعددة اختبار جيب مع تسارع ثابت وإزاحة ثابتة. يتم حساب الحد الأقصى للتسارع لكل مقطع كما هو مذكور أعلاه ، ثم يتم تحديد القيمة القصوى من A1 و A2MAX و A3MAX كأقصى تسارع لظروف الاختبار. وبالمثل ، يتم حساب الحد الأقصى للإزاحة من D1MAX و D2MAX و D ، ويتم تحديد القيمة القصوى كأقصى إزاحة لظروف الاختبار.

حساب الحد الأقصى لتسارع الاهتزاز العشوائي هو كما يلي:
بالنسبة لظروف اختبار الاهتزاز العشوائي مع نطاق تردد معين وقيمة الكثافة الطيفية وقيمة تسارع متوسط الجذر التربيعي (ARMS) ، فإن قيمة ARMS هي الحد الأقصى للتسارع المطلوب. إذا لم يتم توفير قيمة ARMS ، فيجب حسابها بشكل منفصل. يمكن إدخال ظروف الاختبار في أداة التحكم في اختبار الاهتزاز العشوائي (البرنامج) لحساب قيمة التسارع التربيعي لجذر ARMS وسعة اهتزاز Drms.

1. Calculate the acceleration value a based on the user's specified requirements. The test conditions are as follows:
20-80Hz, 3 dB/oct; 80-350Hz, 0.04g²/Hz; 350-2000Hz, -3 dB/oct.

2. الحساب على النحو التالي:
1) للطيف الصاعد (المنحدر N1 ديسيبل / أكتوبر):
حيث م = N1 / 3.
 Then, F1 = 0.04×80[1-(20/80)²]/(1+1) = 1.5.
2) للطيف المسطح:
   F2 = P(f3 - f2) = 0.04×(350-80) = 10.8.
3) للطيف الهابط (المنحدر -N2 ديسيبل / أكتوبر):
From F3 = 0.04×350[-ln(350/2000)] = 24.5.
The formula for a is a = √(F1 + F2 + F3).
Therefore, a = √(1.5 + 10.8 + 24.5) = 6.06g.

3. According to Newton's second law (F = ma), calculate the force F:
 F = (M1 + M2 + M3)×a,
 أين:
 M1 - وزن الأجزاء المتحركة للمنصة الكهربائية (كجم).
 M2 - وزن منصة التمدد الرأسية أو منصة الشريحة الأفقية أو التركيبات (كجم).
 M3 - الحد الأقصى لوزن عينة الاختبار (كجم).
 a - Maximum acceleration of the vibration test (m/s²).

يجب أن تكون القوة F أقل من أو تساوي أقصى قوة إثارة جيبية للمنصة الكهربائية.
For random vibration, the force Frms is calculated as Frms = M×Arms and should be less than the rated random excitation force of the electric platform.

4. تأكد من أن الحد الأقصى للإزاحة للمنصة الكهربائية أكبر من الحد الأقصى للإزاحة في ظروف الاختبار. بالنسبة للاهتزاز العشوائي ، يجب أن يكون جذر متوسط السعة التربيعية Drms المحسوبة بواسطة الكمبيوتر أقل من ثلث السعة المقدرة للمنصة الكهربائية.

5. حدد أداة تحكم جيبية أو أداة تحكم عشوائية في الاهتزاز بناء على ظروف الاختبار المحددة. إذا كانت هناك معلمات للاهتزاز العشوائي ، فيجب اختيار أداة تحكم عشوائية في الاهتزاز.

استنتاج

عند اختيار جهاز اختبار اهتزاز عالي التردد ، من الأهمية بمكان مراعاة المتطلبات المحددة لصناعتك ، بما في ذلك ظروف الاختبار ، وحساب اختيار المنصة الكهربائية ، وحساب القوة ، والحاجة إلى التحكم في الاهتزاز الجيبي أو العشوائي. باتباع دليل الشراء هذا والنظر في المواصفات والمتطلبات التفصيلية ، يمكنك اختيار أنسب جهاز اختبار اهتزاز عالي التردد لصناعتك.

يرجى ملاحظة أن هذا الدليل يوفر معلومات مفصلة بناء على احتياجات الصناعة ونقاط الألم والمعايير الدولية. يوصى بدراسة أدلة المنتج والمواصفات ذات الصلة للتأكد من أن المعدات المشتراة تلبي متطلباتك المحددة قبل الاستخدام الفعلي.

تواصل معنا